Verkauf : +44 191 418 1198         Email :

Menu

www.canford.de

3 November 2024
  • LIEFERUNG AM NÄCHSTEN TAG
    MÖGLICH
  • ENGAGIERTE DEUTSCHSPRACHIGE
    KUNDENBETREUUNG
  • EINZIGARTIGE MÖGLICHKEITEN
    DURCH EIGENE FERTIGUNG
  • KOSTENFREIE TECHNISCHE BERATUNG
    VON UNSEREM EXPERTENTEAM

iPower Lite IPL-003-IP1-0F POWER DISTRIBUTION UNIT Vertical, 12x C13 2x C19, 16A inlet

Artikelnummer
42-6105
Hersteller
iPower
Typennummer
  • IPL-003-IP1-0F
iPower Lite IPL-003-IP1-0F POWER DISTRIBUTION UNIT Vertical, 12x C13 2x C19, 16A inlet
iPower Lite IPL-003-IP1-0F POWER DISTRIBUTION UNIT Vertical, 12x C13 2x C19, 16A inlet

IPOWER LITE INTELLIGENT POWER DISTRIBUTION UNITS

These are entry-level, IP addressable PDUs, designed and manufactured in the UK, providing cost-effective local and remote power monitoring. They monitor overall PDU performance and allow for minimum / maximum level thresholds to be set for volts RMS, amps RMS, kilowatts, frequency and power factor. In addition they monitor peak volts, peak current, kVA and PDU temperature. A 5 year RTB warranty is offered.

The PDUs are easily configured, with set-up completed in minutes. A local display is fitted to allow local monitoring. The units may also be monitored remotely using the SNMP software which is included free of charge; multiple PDUs may be monitored from a single IP address. The software offers the facility for email alerts to be sent, alerts on all parameters and also allows monitoring of temperature and humidity thresholds. iPLite communicates via HTML, HTTPs, SNMP and XML via the inbuilt web browser.

Cases are manufactured using mild steel. Power inlets use Neutrik PowerCon connectors rated at either 16A or 32A. Grounding studs (M6) are provided at one end.

Model Type IEC C13 IEC C19 PowerCon Power Depth Width Height Fixing Overall Body
outlets outlets inlets sockets (mm) (mm) (U) centres height length
(mm) (mm) (mm)
IPL-001-IP1-0F Horizontal 10 2 1x 16A Rear 100 482.6 1 465 - -
IPL-001-IP1-0G Horizontal 10 2 1x 32A Rear 100 482.6 1 465 - -
IPL-002-IP1-0F Horizontal 12 2 1x 16A Front 100 482.6 2 465 - -
IPL-002-IP1-0G Horizontal 12 2 1x 32A Front 100 482.6 2 465 - -
IPL-003-IP1-0F Vertical 12 2 1x 16A Front 56 44.5 992 911 - 971 980 880
IPL-003-IP1-0G Vertical 12 2 1x 32A Front 56 44.5 992 911 - 971 980 880
IPL-004-IP1-0F Vertical 24 4 1x 16A Front 56 44.5 1402 1321 - 1381 1390 1290
IPL-004-IP1-0G Vertical 24 4 1x 32A Front 56 44.5 1402 1321 - 1381 1390 1290
IPL-005-IP1-0G Vertical 36 6 1x 32A Front 56 44.5 1822 1741 - 1801 1810 1710
The PDUs are supplied without power leads.

Required accessories: Power input cables, see Powercon AC mains power leads.
Optional accessories: Power output cables, see IEC jumper cables.